← Home

FCSEL

Floating-point conditional select (scalar)

This instruction allows the SIMD&FP destination register to take the value from either one or the other of two SIMD&FP source registers. If the condition passes, the first SIMD&FP source register value is taken, otherwise the second SIMD&FP source register value is taken.

Depending on the settings in the CPACR_EL1, CPTR_EL2, and CPTR_EL3 registers, and the current Security state and Exception level, an attempt to execute the instruction might be trapped.

313029282726252423222120191817161514131211109876543210
00011110ftype1Rmcond11RnRd
MS

Half-precision encoding

(FEAT_FP16)

(ftype == 11)

FCSEL <Hd>, <Hn>, <Hm>, <cond>

Single-precision encoding

(FEAT_FP)

(ftype == 00)

FCSEL <Sd>, <Sn>, <Sm>, <cond>

Double-precision encoding

(FEAT_FP)

(ftype == 01)

FCSEL <Dd>, <Dn>, <Dm>, <cond>

Decode (all encodings)

if !IsFeatureImplemented(FEAT_FP) then EndOfDecode(Decode_UNDEF); end; if ftype == '10' then EndOfDecode(Decode_UNDEF); end; if ftype == '11' && !IsFeatureImplemented(FEAT_FP16) then EndOfDecode(Decode_UNDEF); end; let d : integer{} = UInt(Rd); let n : integer{} = UInt(Rn); let m : integer{} = UInt(Rm); let datasize : integer{} = 8 << UInt(ftype XOR '10'); let condition : bits(4) = cond;

Assembler Symbols

<Hd>

Is the 16-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Hn>

Is the 16-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Hm>

Is the 16-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

<cond>

Is one of the standard conditions, encoded in the standard way, and encoded in cond:

cond <cond>
0000 EQ
0001 NE
0010 CS|HS
0011 CC|LO
0100 MI
0101 PL
0110 VS
0111 VC
1000 HI
1001 LS
1010 GE
1011 LT
1100 GT
1101 LE
1110 AL
1111 NV
<Sd>

Is the 32-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Sn>

Is the 32-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Sm>

Is the 32-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

<Dd>

Is the 64-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Dn>

Is the 64-bit name of the first SIMD&FP source register, encoded in the "Rn" field.

<Dm>

Is the 64-bit name of the second SIMD&FP source register, encoded in the "Rm" field.

Operation

AArch64_CheckFPEnabled(); var result : bits(datasize); let condition_holds : boolean = ConditionHolds(condition); result = if condition_holds then V{datasize}(n) else V{datasize}(m); V{datasize}(d) = result;

Operational information

This instruction is a data-independent-time instruction as described in About PSTATE.DIT.


Version 2026.09 — Copyright © 2010-2026 Arm Limited or its affiliates.

This site is provided as a community resource and is NOT affiliated with nor endorsed by Arm Limited.